Motor type

Asynchronous induction motor or synchronous permanent magnet motor

Voltage

0 to U1, 3-phase symmetrical, Umax at the field weakening point

Short-circuit protection

The motor output is short-circuit proof by IEC 61800-5-1

Frequency

0...400Hz

Frequency resolution

0.01Hz

Current

Refer to Ratings

Power limit

1.5·PN

Field weakening point

10...400Hz

Carrier frequency

4, 8, 12 or 15kHz


B.4.1 EMC compatibility and motor cable length

To comply with the European EMC Directive (standard IEC/EN 61800-3), use the following maximum motor cable lengths for 4kHz switching frequency.

All frame sizes (with external EMC filter)

Maximum motor cable length, 4kHz

Second environment (category C3)

30

First environment (category C2)

30

Maximum motor cable length is determined by the drive’s operational factors. Contact the local representative for the exact maximum lengths when using external EMC filters.


上一章节 下一章节